UPS monitoring software for the fleet you actually run.

Every UPS on one screen, on your own network. MayaUPS reads SNMP v1/v2c/v3, RFC 1628, USB and serial data, turns device alarms into plain messages and keeps track of battery age. Monitoring and controlled shutdown run entirely on site, so a WAN outage, a central service failure or an expired account cannot stop them. When you run several sites, an optional Cloud portal shows them together, hosted in Quebec.

app.local / fleet

Fleet overview

Demo data - 5 devices - 1 on battery - 1 warning

DeviceLoadRuntimeStatus
Rack A - Core
APC UPS
42%
38 minOnline
Rack B - Edge
Eaton UPS
61%
21 minOn battery
MDF
Vertiv / Liebert
34%
51 minOnline
Facilities
CyberPower UPS
55%
29 minWarning
Utility Room
XPC UPS
48%
33 minOnline
Server Room B
Tripp Lite UPS
39%
44 minOnline
Print Room
Delta UPS
22%
58 minOnline
IDF West
RFC-1628 UPS
27%
64 minOnline
Active alerts
2
Fleet runtime - 24 h
Load by device
Rack
Rack
MDF
Facilities

The software, as it actually runs

Real screenshots of MayaUPS at work, captured from the built-in demo environment. No mockups.

MayaUPS fleet overview: UPS devices grouped by site with status, battery, runtime and load
Fleet overview: every UPS on one screen, with status, battery, runtime, load and the last reading, grouped by site.
MayaUPS device detail: identity, live values and per-phase input readings
Device detail: identity, live values and per-phase input readings, with the card profile that decodes the data.
MayaUPS fleet health page: devices ranked at risk, attention and healthy, with reasons and suggested actions
Fleet health: every device is ranked, with the reasons (battery end of life, open alarm, expired warranty) and a suggested action.
MayaUPS planning page: timeline of battery end of life, warranty expiries and maintenance with estimated costs
Planning: battery end of life, warranties and preventive maintenance on one timeline, with estimated replacement costs and CSV export.
MayaUPS alarms page: active alarms with severity, acknowledgement and recent history
Alarms: conditions decoded into readable messages (fan, charger, bypass), severity, acknowledgement and history.
MayaUPS controlled shutdown page: active kill switch and policies in observe mode
Controlled shutdown: a kill switch, watch-only mode, test runs that switch nothing off, and a log of every step before anything acts on its own.
The same fleet view with the interface in French
The same console in French or English: the operator picks the language, the data stays identical.

CORE FUNCTIONS

What operators can see and manage.

SNMP

Every brand on one screen

Your APC, Eaton, Vertiv/Liebert, XPC, Tripp Lite, Delta and CyberPower units in one view, with anything RFC 1628 alongside them. One tool, not one per brand on the rack.

Batteries

Know which batteries are next

Installation dates, expected service life, temperature and service history add up to a short list: the batteries to replace before they fail on you.

Shutdown

Rehearse the shutdown first

Test your shutdown plan while it cannot touch anything. Arm it only after you have watched it do the right thing.

Alerts

Alerts that respect your inbox

Related events arrive as one message. You hear when things return to normal, and problems that stay active get escalated instead of repeated.

Cloud

Several sites, one screen, if you want it

A site can opt in to send a short status summary to the MayaUPS Cloud portal, hosted in Quebec. It carries no measurements and no history, and nothing can come back down it. Leave it off and nothing leaves the building.

Installation

Runs where you need it

Install it on Windows or Linux as a single program. The web interface and database are built in, so there is no separate virtual appliance to stand up or maintain, and your team picks English or French.

UPS FIELD SERVICES

When the software finds the problem, someone still has to fix it.

MayaUPS tells you the condition, the alarms, the battery age and the maintenance timing. Inspecting, installing, commissioning and repairing the equipment is still work for a qualified technician.

Service and installation

A technician on site confirms what the readings mean at the machine itself and does the physical work safely.

  • Preventive service and fault investigation
  • UPS installation and electrical integration
  • Battery replacement and disposal planning

Commissioning and configuration

A new or modified UPS should be proven as a complete system before you depend on it.

  • Start-up and operating tests
  • Network card, SNMP and alarm configuration
  • Settings and service records handed to your site team

UPS service, installation, commissioning and configuration across Canada

When you call, have the UPS model, the site, the active alarms and the work you need in hand. It shortens everything.

UPS BATTERIES

A battery that fits is not automatically the right UPS battery.

A UPS asks its batteries for a lot of power in a short burst. Picking a replacement is about the discharge rating and construction specified for your exact model, not voltage and amp-hours alone.

High-rate, flame-retardant UPS batteries

High-rate batteries are built for short, hard discharges; their data sheets quote watts per cell over periods like 10 or 15 minutes. A flame-retardant case must be confirmed on the exact model or option. The chemistry alone does not tell you.

General-purpose standby batteries

General-purpose batteries cover a broad range of standby duty, security panels and emergency lighting included. Some come in flame-retardant cases. But a matching case size, voltage or amp-hour rating does not by itself prove the UPS power or runtime requirement.

Find the correct UPS replacement battery

Before you order, match the UPS or approved cartridge, the voltage, the short-duration discharge rating, the dimensions, the terminals, the expected service life and the specified case material.

CHOOSING A TOOL

MayaUPS suits sites that operate more than one UPS brand.

Compare MayaUPS with APC PowerChute, Eaton IPM and Vertiv Power Assist for coverage, daily work, shutdown and price.

See the comparison
English and French interfaceRuns locallySNMP v1/v2c/v3Windows and LinuxData under your control

See MayaUPS on your own fleet.

Tell us what you run and we send you the signed installer, with notes for your equipment.

Get MayaUPS

Frequently asked questions

How much does MayaUPS cost?

Tell us how many UPS units you run and where they are. You get a written proposal for your fleet, not a rate card that fits nobody.

Does MayaUPS run in the cloud?

It runs on your own network, and monitoring and shutdown never depend on anything outside it. There is also an optional Cloud portal, in limited beta, that puts several sites on one screen: read-only, hosted in Quebec, and off until you switch it on. Your sites behave the same whether you use it or not.

Which operating systems are supported?

Windows and Linux, including Docker on Linux. The optional agent that shuts your servers down in order runs on Windows and Linux too.